Selection and Usage Guide
Door Style Recommended Door Usage Recommended Gage of Frame
Level 1 - Standard Duty
Model 1 - Full Flush DM / DL 420, DE 820 / 18 (Honeycomb, styrene, or urethane core) 16 / 18 gage - 1.3mm / 1mm
Model 2 - Seamless DM / DL 420, DE 820 / 18 (Honeycomb, styrene, or urethane core) 16 / 18 gage - 1.3mm / 1mm
Level 2 - Heavy Duty
Model 1 - Full Flush DM / DL / DE 418 (Honeycomb, styrene, or urethane core) Embossed 2, 6, & 8 panels 16 gage - 1.3mm
Model 2 - Seamless DM / DL / DE 418 (Honeycomb, styrene, or urethane core) Embossed 2, 6, & 8 panels 16 gage - 1.3mm
Level 3 - Extra-Heavy Duty
Model 1 - Full Flush DL / DE 416 (Honeycomb, styrene or urethane core) 14 / 16 gage - 1.7mm / 1.3mm
Model 2 - Seamless DL / DE 416 (Honeycomb, styrene or urethane core) 14 / 16 gage - 1.7mm / 1.3mm
Level 4 - Maximum Duty
Model 1 - Flush DE 414 (Honeycomb, styrene or urethane core) 14 / 16 gage - 1.7mm / 1.3mm
Model 2 - Seamless DE 414 (Honeycomb, styrene or urethane core) 14 / 16 gage - 1.7mm / 1.3mm

Door Selections

The following charts show recommended Republic doors for a variety of entry locations. Simply locate the entry way requirement on the charts below, then find the doors must suitable for the specified usage. Please refer to the codes listed below for Republic recommended door construction and design nomenclature.

Republic Door Construction and Design Nomenclature

Recommended Republic Door Construction
1 = DM / DL / DE 420
2 = DM / DL / DE 418
3 = DL / DE 416
4 = DE 414

Door Design Nomenclature
F = Flush
G = Half Glass
V = Vision Lite
FG = Full Glass
N = Narrow Lite

Apartment Buildings
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X     X   X  
Unit Entrance X X     X        
Stairwell   X X       X    
Bathroom X       X        
Bedroom X       X        
Interior Rooms X       X        
Closet X       X        
Storage         X        
Laundry / Utility X       X X X   X
Garage / Parking         X   X   X
Back to Top
Hotels / Motels
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance   X X   X   X X X
Unit Entrance X X     X   X    
Secondary Entrance / Exit     X X X   X    
Stairwell   X X       X    
Fire Exit   X X   X   X   X
Smoke Barrier (Double Egress)   X     X   X    
Bath X       X   X    
Connecting Rooms X       X   X    
Closet X       X   X    
Kitchen   X X   X X X    
Office X       X X X    
Storage / Utility   X X X X   X    
Laundry   X X   X   X    
Pool Area / Equipment   X     X   X    
Back to Top
Health Care Facilities
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X     X   X X
Service Entrance     X X X   X    
Stairwell   X X       X    
Corridor   X X   X X X   X
Bedroom X       X        
Patient Room   X     X        
Operating & Exam Rooms   X X   X        
Pharmacy     X X X   X    
Recreation / Lounges   X     X   X    
Closet X       X        
Kitchen   X X       X    
Back to Top
Dormitories
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X X       X X
Unit Entrance X X     X        
Stairwell   X X       X   X
Bathroom X       X        
Bedroom X       X        
Closet X       X        
Back to Top
Schools
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X     X   X X
Secondary Entrance / Exit     X X X   X    
Stairwell   X X       X   X
Restroom   X     X        
Classroom   X             X
Locker Room   X X            
Closet X       X        
Cafeteria / Kitchen X X       X     X
Storage / Utility   X     X        
Boiler Room   X X   X        
Back to Top
Industrial / Offices
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X     X   X  
Secondary Entrance     X X X   X    
Stairwell   X X       X    
Restroom   X X   X        
Individual Office X       X        
Closet X       X        
Back to Top
Industrial Manufacturing
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X         X X
Secondary Entrance     X X X        
Restroom     X   X        
Cafeteria     X     X      
Equipment Room X X     X        
Boiler Room     X   X        
Parts Crib   X     X        
Tool Room         X X      
Back to Top
Office Buildings
Usage Door Construction Level Door Design Nomenclature
  1 2 3 4 F G V FG N
Main Entrance     X     X   X X
Service / Supply Entrance     X X X        
Stairwell   X X       X    
Restroom   X X            
Individual Office X       X        
Closet X       X        
Equipment Room   X X     X      
Boiler Room   X X   X        
Back to Top

Flush Frame Selections

The following charts show recommended Republic frames for a variety of wall constructions. Locate the wall requirements on the charts below, then find the frame most suitable for the specified usage.

Flush (ME Series) Frames
Wall Detail and Type Frame Depth (size of Frame to Specify)
Wrap around concrete block
4" (100 mm) masonry unit X        
6" (150 mm) masonry unit     X    
8" (200 mm) masonry unit         X
Butted Masonry
6" (150 mm) masonry unit X X      
8" (200 mm) masonry unit X X X X  
Cavity wall, 4" (100 mm) masonry units     X X X
Cavity wall, 6" (150 mm) masonry units         X
Concrete block and tile
Cavity wall, 4" (100 mm) masonry units X        
4" (100 mm) masonry unit, brick veneer, plaster inside   X      
4" (100 mm) masonry unit, brick veneer     X    
Cavity wall, 4" (100 mm) masonry unit, brick veneer       X  
Existing wall
Poured concrete or concrete block X X X X X
Wood / Steel stud walls
2" x 3" (50 mm x 75 mm) wood stud, ½" wall board each side X        
Closed steel stud, gypsum X X X X  
2" x 4" (50 mm x 100 mm) wood stud, gypsum   X      
2" x 4" (50 mm x 100 mm) wood stud, gypsum, brick veneer     X X  
2" x 6" (50 mm x 150 mm) wood stud, 5/8" (16 mm) gypsum       X  
2" x 6" (50 mm x 150 mm) wood stud, ½" (13 mm) & 5/8" (16 mm) gypsum 2 side       X  
Back to Top

Drywall Frame Selections

The following charts show recommended Republic frames for various wall constructions. Locate the wall requirements on the charts below, then find the most suitable for the specified usage.

Drywall (MH Series) Frames
Stud Thickness Frame Depth
(Size of Frame to Specify)
Size Type Drywall Wall
1 Layer of gypsum board each side of the wall
1 5/8" (41 mm) Steel ½" (13 mm) 2 5/8" (67 mm) 3 5/8" (91 mm)
1 5/8" (41 mm) Steel 5/8" (16 mm) 2 7/8" (73 mm) 3 7/8" (96 mm)
2½" (63 mm) Wood or Steel ½" (13 mm) 3½" (89 mm) 4½" (114 mm)
2½" (63 mm) Wood or Steel 5/8" (16 mm) 3¾" (95 mm) 4¾" (121 mm)
2½" (63 mm) Wood or Steel ¾" (19 mm) 4" (102 mm) 5" (127 mm)
3½" (88 mm) Wood ½" (13 mm) 4½" (114 mm) 5½" (140 mm)
3½" (88 mm) Wood 5/8" (16 mm) 4¾" (121 mm) 5¾" (146 mm)
3 5/8" (88 mm) Steel 5/8" (16 mm) 4 7/8" (124 mm) 5 7/8" (149 mm)
1 Layer of gypsum board one side of the wall and 2 on the other side of the wall
2½" (63 mm) Wood or Steel ½" (13 mm) 4" (102 mm) 5" (127 mm)
3½" (88 mm) Wood ½" (13 mm) 5" (127 mm) 6" (152 mm)
2 Layers of gypsum board each side of the wall
2½" (63 mm) Wood or Steel 5/8" (16 mm) 5" (127 mm) 6" (152 mm)
3 5/8" (91 mm) Steel 5/8" (16 mm) 6 1/8" (156 mm) 7 1/8" (181 mm)
3 Layers of gypsum board each side of the wall
1 5/8" (41mm) Steel ½" (13 mm) 4 5/8" (117 mm) 5 5/8" (143 mm)
Back to Top