Selection and Usage Guides
The following selection and usage guides have been put together as tools for preparing architectural specifications for hollow metal doors, frames and stick systems.
The following charts show recommended Republic doors and frames for a variety of entry locations and wall construction. Locate the entry way or wall requirements on the charts, then find the doors and frames most suitable to the application.
View Door Guides: Apartment Buildings - Hotels / Motels - Health Care Facilities - Dormitories - Schools - Industrial / Offices - Industrial Manufacturing - Office Buildings
View Frame Guides: Flush Frame - Drywall Frame
Selection and Usage Guide
| Door Style |
Recommended Door Usage |
Recommended Gage of Frame |
| Level 1 - Standard Duty |
| Model 1 - Full Flush |
DM / DL 420, DE 820 / 18 (Honeycomb, styrene, or urethane core) |
16 / 18 gage - 1.3mm / 1mm |
| Model 2 - Seamless |
DM / DL 420, DE 820 / 18 (Honeycomb, styrene, or urethane core) |
16 / 18 gage - 1.3mm / 1mm |
| Level 2 - Heavy Duty |
| Model 1 - Full Flush |
DM / DL / DE 418 (Honeycomb, styrene, or urethane core) Embossed 2, 6, & 8 panels |
16 gage - 1.3mm |
| Model 2 - Seamless |
DM / DL / DE 418 (Honeycomb, styrene, or urethane core) Embossed 2, 6, & 8 panels |
16 gage - 1.3mm |
| Level 3 - Extra-Heavy Duty |
| Model 1 - Full Flush |
DL / DE 416 (Honeycomb, styrene or urethane core) |
14 / 16 gage - 1.7mm / 1.3mm |
| Model 2 - Seamless |
DL / DE 416 (Honeycomb, styrene or urethane core) |
14 / 16 gage - 1.7mm / 1.3mm |
| Level 4 - Maximum Duty |
| Model 1 - Flush |
DE 414 (Honeycomb, styrene or urethane core) |
14 / 16 gage - 1.7mm / 1.3mm |
| Model 2 - Seamless |
DE 414 (Honeycomb, styrene or urethane core) |
14 / 16 gage - 1.7mm / 1.3mm |
Door Selections
The following charts show recommended Republic doors for a variety of entry locations. Simply locate the entry way requirement on the charts below, then find the doors must suitable for the specified usage. Please refer to the codes listed below for Republic recommended door construction and design nomenclature.
Republic Door Construction and Design Nomenclature
Recommended Republic Door Construction
1 = DM / DL / DE 420
2 = DM / DL / DE 418
3 = DL / DE 416
4 = DE 414
Door Design Nomenclature
F = Flush
G = Half Glass
V = Vision Lite
FG = Full Glass
N = Narrow Lite
Apartment Buildings
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
X |
|
X |
|
| Unit Entrance |
X |
X |
|
|
X |
|
|
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
|
| Bathroom |
X |
|
|
|
X |
|
|
|
|
| Bedroom |
X |
|
|
|
X |
|
|
|
|
| Interior Rooms |
X |
|
|
|
X |
|
|
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
| Storage |
|
|
|
|
X |
|
|
|
|
| Laundry / Utility |
X |
|
|
|
X |
X |
X |
|
X |
| Garage / Parking |
|
|
|
|
X |
|
X |
|
X |
Back to Top
Hotels / Motels
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
X |
X |
|
X |
|
X |
X |
X |
| Unit Entrance |
X |
X |
|
|
X |
|
X |
|
|
| Secondary Entrance / Exit |
|
|
X |
X |
X |
|
X |
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
|
| Fire Exit |
|
X |
X |
|
X |
|
X |
|
X |
| Smoke Barrier (Double Egress) |
|
X |
|
|
X |
|
X |
|
|
| Bath |
X |
|
|
|
X |
|
X |
|
|
| Connecting Rooms |
X |
|
|
|
X |
|
X |
|
|
| Closet |
X |
|
|
|
X |
|
X |
|
|
| Kitchen |
|
X |
X |
|
X |
X |
X |
|
|
| Office |
X |
|
|
|
X |
X |
X |
|
|
| Storage / Utility |
|
X |
X |
X |
X |
|
X |
|
|
| Laundry |
|
X |
X |
|
X |
|
X |
|
|
| Pool Area / Equipment |
|
X |
|
|
X |
|
X |
|
|
Back to Top
Health Care Facilities
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
X |
|
X |
X |
| Service Entrance |
|
|
X |
X |
X |
|
X |
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
|
| Corridor |
|
X |
X |
|
X |
X |
X |
|
X |
| Bedroom |
X |
|
|
|
X |
|
|
|
|
| Patient Room |
|
X |
|
|
X |
|
|
|
|
| Operating & Exam Rooms |
|
X |
X |
|
X |
|
|
|
|
| Pharmacy |
|
|
X |
X |
X |
|
X |
|
|
| Recreation / Lounges |
|
X |
|
|
X |
|
X |
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
| Kitchen |
|
X |
X |
|
|
|
X |
|
|
Back to Top
Dormitories
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
X |
|
|
|
X |
X |
| Unit Entrance |
X |
X |
|
|
X |
|
|
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
X |
| Bathroom |
X |
|
|
|
X |
|
|
|
|
| Bedroom |
X |
|
|
|
X |
|
|
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
Back to Top
Schools
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
X |
|
X |
X |
| Secondary Entrance / Exit |
|
|
X |
X |
X |
|
X |
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
X |
| Restroom |
|
X |
|
|
X |
|
|
|
|
| Classroom |
|
X |
|
|
|
|
|
|
X |
| Locker Room |
|
X |
X |
|
|
|
|
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
| Cafeteria / Kitchen |
X |
X |
|
|
|
X |
|
|
X |
| Storage / Utility |
|
X |
|
|
X |
|
|
|
|
| Boiler Room |
|
X |
X |
|
X |
|
|
|
|
Back to Top
Industrial / Offices
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
X |
|
X |
|
| Secondary Entrance |
|
|
X |
X |
X |
|
X |
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
|
| Restroom |
|
X |
X |
|
X |
|
|
|
|
| Individual Office |
X |
|
|
|
X |
|
|
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
Back to Top
Industrial Manufacturing
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
|
|
X |
X |
| Secondary Entrance |
|
|
X |
X |
X |
|
|
|
|
| Restroom |
|
|
X |
|
X |
|
|
|
|
| Cafeteria |
|
|
X |
|
|
X |
|
|
|
| Equipment Room |
X |
X |
|
|
X |
|
|
|
|
| Boiler Room |
|
|
X |
|
X |
|
|
|
|
| Parts Crib |
|
X |
|
|
X |
|
|
|
|
| Tool Room |
|
|
|
|
X |
X |
|
|
|
Back to Top
Office Buildings
| Usage |
Door Construction Level |
Door Design Nomenclature |
| |
1 |
2 |
3 |
4 |
F |
G |
V |
FG |
N |
| Main Entrance |
|
|
X |
|
|
X |
|
X |
X |
| Service / Supply Entrance |
|
|
X |
X |
X |
|
|
|
|
| Stairwell |
|
X |
X |
|
|
|
X |
|
|
| Restroom |
|
X |
X |
|
|
|
|
|
|
| Individual Office |
X |
|
|
|
X |
|
|
|
|
| Closet |
X |
|
|
|
X |
|
|
|
|
| Equipment Room |
|
X |
X |
|
|
X |
|
|
|
| Boiler Room |
|
X |
X |
|
X |
|
|
|
|
Back to Top
The following charts show recommended Republic frames for a variety of wall constructions. Locate the wall requirements on the charts below, then find the frame most suitable for the specified usage.
- Notes:
- Size of frame to specify will vary with stud size
- Frames can also be used in wall conditions other than those shown below
- Frames for these walls can be KD (knock-down) or SUA (welded)
Flush (ME Series) Frames
| Wall Detail and Type |
Frame Depth (size of Frame to Specify) |
| Wrap around concrete block |
4¾ |
5¾ |
6¾ |
7¾ |
8¾ |
| 4" (100 mm) masonry unit |
X |
|
|
|
|
| 6" (150 mm) masonry unit |
|
|
X |
|
|
| 8" (200 mm) masonry unit |
|
|
|
|
X |
| Butted Masonry |
4¾ |
5¾ |
6¾ |
7¾ |
8¾ |
| 6" (150 mm) masonry unit |
X |
X |
|
|
|
| 8" (200 mm) masonry unit |
X |
X |
X |
X |
|
| Cavity wall, 4" (100 mm) masonry units |
|
|
X |
X |
X |
| Cavity wall, 6" (150 mm) masonry units |
|
|
|
|
X |
| Concrete block and tile |
4¾ |
5¾ |
6¾ |
7¾ |
8¾ |
| Cavity wall, 4" (100 mm) masonry units |
X |
|
|
|
|
| 4" (100 mm) masonry unit, brick veneer, plaster inside |
|
X |
|
|
|
| 4" (100 mm) masonry unit, brick veneer |
|
|
X |
|
|
| Cavity wall, 4" (100 mm) masonry unit, brick veneer |
|
|
|
X |
|
| Existing wall |
4¾ |
5¾ |
6¾ |
7¾ |
8¾ |
| Poured concrete or concrete block |
X |
X |
X |
X |
X |
| Wood / Steel stud walls |
4¾ |
5¾ |
6¾ |
7¾ |
8¾ |
| 2" x 3" (50 mm x 75 mm) wood stud, ½" wall board each side |
X |
|
|
|
|
| Closed steel stud, gypsum |
X |
X |
X |
X |
|
| 2" x 4" (50 mm x 100 mm) wood stud, gypsum |
|
X |
|
|
|
| 2" x 4" (50 mm x 100 mm) wood stud, gypsum, brick veneer |
|
|
X |
X |
|
| 2" x 6" (50 mm x 150 mm) wood stud, 5/8" (16 mm) gypsum |
|
|
|
X |
|
| 2" x 6" (50 mm x 150 mm) wood stud, ½" (13 mm) & 5/8" (16 mm) gypsum 2 side |
|
|
|
X |
|
Back to Top
The following charts show recommended Republic frames for various wall constructions. Locate the wall requirements on the charts below, then find the most suitable for the specified usage.
- Notes:
- Size of frame to specify will vary with stud size
- Frames can also be used in wall conditions other than those shown below
- Frames for these walls can be KD (knock-down) or W (welded)
Drywall (MH Series) Frames
| Stud |
Thickness |
Frame Depth
(Size of Frame to Specify) |
| Size |
Type |
Drywall |
Wall |
| 1 Layer of gypsum board each side of the wall |
| 1 5/8" (41 mm) |
Steel |
½" (13 mm) |
2 5/8" (67 mm) |
3 5/8" (91 mm) |
| 1 5/8" (41 mm) |
Steel |
5/8" (16 mm) |
2 7/8" (73 mm) |
3 7/8" (96 mm) |
| 2½" (63 mm) |
Wood or Steel |
½" (13 mm) |
3½" (89 mm) |
4½" (114 mm) |
| 2½" (63 mm) |
Wood or Steel |
5/8" (16 mm) |
3¾" (95 mm) |
4¾" (121 mm) |
| 2½" (63 mm) |
Wood or Steel |
¾" (19 mm) |
4" (102 mm) |
5" (127 mm) |
| 3½" (88 mm) |
Wood |
½" (13 mm) |
4½" (114 mm) |
5½" (140 mm) |
| 3½" (88 mm) |
Wood |
5/8" (16 mm) |
4¾" (121 mm) |
5¾" (146 mm) |
| 3 5/8" (88 mm) |
Steel |
5/8" (16 mm) |
4 7/8" (124 mm) |
5 7/8" (149 mm) |
| 1 Layer of gypsum board one side of the wall and 2 on the other side of the wall |
| 2½" (63 mm) |
Wood or Steel |
½" (13 mm) |
4" (102 mm) |
5" (127 mm) |
| 3½" (88 mm) |
Wood |
½" (13 mm) |
5" (127 mm) |
6" (152 mm) |
| 2 Layers of gypsum board each side of the wall |
| 2½" (63 mm) |
Wood or Steel |
5/8" (16 mm) |
5" (127 mm) |
6" (152 mm) |
| 3 5/8" (91 mm) |
Steel |
5/8" (16 mm) |
6 1/8" (156 mm) |
7 1/8" (181 mm) |
| 3 Layers of gypsum board each side of the wall |
| 1 5/8" (41mm) |
Steel |
½" (13 mm) |
4 5/8" (117 mm) |
5 5/8" (143 mm) |
Back to Top